Tissue characterization by photographic imaging during treatment of chronic venous ulcer: technical note

Caracterização tecidual de imagem fotográfica durante tratamento de úlcera venosa crônica: nota técnica

Fernanda Thaysa Avelino dos Santos; Camila Ataíde Rocha; Sergio Xavier Salles Cunha; Thays Fernanda Avelino dos Santos; Charles Hamilton Mélo Júnior; Jéssika Medeiros de Barros Lima; Adriana Melo Barbosa Costa; Guilherme Benjamin Brandão Pitta

Downloads: 0
Views: 832

Abstract

Chronic venous ulcers are a medical challenge with a socioeconomic impact. Tissue characterization was quantified by photographic imaging (p-CATIM) of a leg wound treated with Unna boot for 45 days. Three photographs, taken pre-treatment, post Unna boot and post healing were analyzed. Brightness on a 0-255 gray image was re-scaled with black as 0 and adjacent skin as 200. Gray Scale Median (GSM) and the percentages of pixels in each of 14 brightness intervals were calculated. Open ulcer GSM increased from 110 to 159 post Unna boot treatment, reaching 203 post healing. Predominant brightness intervals for the ulcer were 41-153 pre-treatment, 83% of pixels; 133-196 post Unna boot, 80%; and 175-255 post healing, 97%. The GSM of the subcutaneous wound around the ulcer increased from 117 to 137 post healing; the proportion of pixels in the 91-174 interval increased from 67% to 88% (p<0.001). CATIM quantified photographic changes during venous ulcer healing with comparison to the adjacent skin.

Keywords

venous insufficiency, ulcer, photography, quantitative analysis, healing

Resumo

Úlcera de estase na insuficiência venosa crônica constitui desafio médico com impacto socioeconômico. Quantificamos caracterização tecidual por imagem fotográfica (f-CATIM) em ferida de perna tratada com bota de Unna por 45 dias. Três fotografias obtidas pré-tratamento, pós-tratamento com bota e pós-cicatrização foram analisadas. Brilhos em imagem cinza foram recalculados para nova escala no zero preta e 200 para brilho de pele adjacente à ferida. Mediana da escala cinza ou Gray Scale Median (GSM) e proporções de pixels em 14 intervalos de brilho foram estimadas. GSM da úlcera aumentou de 110 para 159 pós-tratamento com bota, atingindo 203 pós-cicatrização. Intervalos predominantes na úlcera: 41-153 pré-tratamento, 83% dos pixels; 133-196 pós-bota, 80%; 175-255 pós-cicatrização, 97%. GSM da ferida subcutânea ao redor da úlcera aumentou de 117 a 137 pós-cicatrização, de 67% a 88% dos pixels no intervalo 91-174 (p<0,001). CATIM quantificou evolução fotográfica de cicatrização de úlcera venosa comparada com pele adjacente.

Palavras-chave

insuficiência venosa, úlcera, fotografia, análise quantitative, cicatrização

References

França LHG, Tavares V. Insuficiência venosa crônica: uma atualização. J Vasc Bras.. 2003;2(4):318-28.

Santos RFFN, Porfírio GJM, Pitta GBB. A diferença na qualidade de vida de pacientes com doença venosa crônica leve e grave. J Vasc Bras.. 2009;8(2):143-7.

Abbade LPF, Lastoria S. Abordagem de pacientes com úlcera da perna de etiologia venosa. An Bras Dermatol.. 2006;81(6):509-22.

Samad A, Hayes S, French L, Dodds S. Digital imaging versus conventional contact tracing for the objective measurement of venous leg ulcers. J Wound Care.. 2002;11(4):137-40.

Griffin JW, Tolley EA, Tooms RE, et al. A comparison of photographic and transparency-based methods for measuring wound surface area. Phys Ther.. 1993;73(2):117-22.

Salles-Cunha SX. Nota técnica: avaliação ultrassonográfica de aneurismas da aorta tratados com endopróteses. J Vasc Bras.. 2012;11(2):150-3.

Lal BK, Hobson RW 2nd, Hameed M, et al. Noninvasive identification of the unstable carotid plaque. Ann Vasc Surg.. 2006;20(2):167-74.

Menezes FH, Silveira TC, Silveira SAF, et al. Comparações preliminares entre a histologia virtual ultrassonográfica in vivo e os achados histopatológicos da placa carotídea produto de endarterectomia. J Vasc Bras.. 2013;12(3):193-201.

Marks NA, Ascher E, Hingorani AP, et al. Gray-scale median of the atherosclerotic plaque can predict success of lumen re-entry during subintimal femoral-popliteal angioplasty. J Vasc Surg.. 2008;47(1):109-16.

Cassou-Birckholz MF, Engelhorn CA, Salles-Cunha SX,. Assessment of deep venous thrombosis by grayscale median analysis of ultrasound images. Ultrasound Q.. 2011;27(1):55-61.

Valiente Engelhorn AL, Engelhorn CA, Salles-Cunha SX,. Ultrasound tissue characterization of the normal kidney. Ultrasound Q.. 2012;28(4):275-80.

Salles-Cunha SX, Silveira AFS, Menezes FH. Ultrasound virtual histology to grade treatment of lower extremity lymphedema. 2012.

Pereira VHH, Costa Filho EM, Santos FTA, et al. Caracterização tecidual de imagem fotográfica durante tratamento do pé diabético ulcerado: nota técnica. J Vasc Bras.. 2013;12(4):303-7.

Beach KW, Paun M, Primozich JF. Principles and instruments of diagnostic ultrasound and doppler ultrasound. Noninvasive vascular diagnosis: a practical guide to therapy. 2007:27.

Salles-Cunha SX, Oliveira HV, Guimarães AF. Valor complementar da termografia no diagnóstico de trombose da veia subclávia: relato de caso. 2013.

Salles-Cunha SX, Oliveira HV. Termografia complementa ultrassonografia arterial e medida de pressões distais em caso de isquemia neurovascular do pé diabético dolorido. 2013.

Sociedade Brasileira de Angiologia e Cirurgia Vascular (SBACV)"> Sociedade Brasileira de Angiologia e Cirurgia Vascular (SBACV)">
5de7f3c00e8825371be31d41 jvb Articles
Links & Downloads

J Vasc Bras

Share this page
Page Sections